Licensed & Insured
California state contractor license
Ice maker not ejecting, completely frozen over, or no water coming in at all? We specialize in GE refrigerators — including Profile and Café. Inlet valves and ice maker assemblies replaced with OEM parts in one visit. If we don't fix it, you don't pay.
California state contractor license
Background check completed
On labor and parts
Parts in the van. Came, fixed, done.
Make sure the ice maker switch is in the ON position and the green indicator is solid (not blinking). A blinking light usually means the module detected a fault.
Gently touch the ice mold from the top. If there's ice but it won't eject — the ejector motor has failed. If the tray is dry — the water supply is blocked.
New GE models (Profile, Café) use RFID-chipped filters. If the filter is expired or a third-party filter without a chip is installed, the system may block water flow to the ice maker entirely.
GE Appliance Tech · Orange
GE French Door ice makers have two common failure patterns. First is the Ice Maker Control Board — located inside the door itself. Condensation gets into the board and it stops sending the signal to the inlet valve. Second is mechanical: the ejector motor or gears strip out and ice locks in the mold.
I carry OEM GE control boards and complete ice maker assemblies. The repair takes about 40 minutes. I also check the inlet valve resistance to rule out a double failure — you don't want to fix the board only to find the valve was leaking too.
Precise diagnosis in 10 minutes.
Specific to newer GE French Door models. The board inside the door is exposed to condensation and fails. Requires board replacement — not just a reset.
Ice forms but won't drop into the bin — stripping gears or a failed ejector motor. We replace the complete module rather than individual gears.
One solenoid coil on the dual inlet valve at the rear has burned out. The dispenser may still work fine while the ice maker gets zero water.
A slowly leaking inlet valve drips water that freezes at the fill tube entrance. No water reaches the mold. We thaw the tube and replace the valve.
Flat labor rate. OEM GE parts. Price confirmed before we start.
| What Failed | Labor (flat) | Part | Total |
|---|---|---|---|
| Ice maker control board | $80 | $80–$140 | $160–$220 |
| Complete ice maker assembly | $80 | $110–$180 | $190–$260 |
| Water inlet valve | $80 | $60–$110 | $140–$190 |
| Fill tube thaw + minor repair | $80 | — | $80 |
Diagnostic fee is $89 — waived when you book the repair.
Similar symptoms? Take a look — we fix it all.
Freezer works, but the fresh-food section is warm
Puddle under the refrigerator
Not making ice or not dispensing water
Humming, clicking, or vibrating
Clicking but won't start, or running with no cooling